A Range of Klargester Package Pump Systems for Residential & Commercial Developments Applications
Pump Station Enquiry:
To allow us to accurately size and quote your specific system, please complete either our Online Pump Station Enquiry Form or alternatively, print our PDF Pump Station Enquiry Form and post or fax it to us.
Once we have received your enquiry form we will then evaluate your requirements and specify the appropriate system accordingly to allow us to provide a suitable quotation.
Pump stations are needed where foul drainage by gravity is not possible, Owls Hall have a large range of pump stations including;
- Domestic sewage pumping
- Effluent pumpsets for sewage treatment plants
- Surface water pumping systems
- Septic tank pumpsets
- 24 hour storage chambers
- Bespoke systems
For temporary storage solutions click here.
- HillMaster
A competitive solution for both domestic and industrial applications. - HillMaster24
A comprehensive range offering advanced solutions for larger domestic and industrial applications. - Effluent Pumpsets
Assist in pumping effluent from a treatment plant. - Domestic Sewage Pumpsets
Assist in pumping crude sewage directly to the main system - Surface Water Pumpsets
Assists in dealing with the pumping of rainwater. - Compact Pump Systems
Assist in dealing with dewatering of buildings
Owls Hall offer a full Installation service. Please visit our Installation section for more information.
All our installations are carried out in accordance with British Water Flows and Loads v4
Features
- Maintenance free GRP and plastic construction chambers
- High-level alarm fitted as standard
- Pre-set Automatic level control
- Non return valve
- Manufactured under the quality procedures of BS ISO9001: 2000
- Ready for immediate and simple installation
- Owls Hall offer a full commissioning and after sales service involving planned maintenance
visits. Please visit our servicing section for more information.
Options
- Wide range of emergency overflow tanks
- 110mm or 160mm inlet connections
- Various invert depths
- Standby replacement pumps
Legal Requirements
Prior to installation, there is a legal requirement to obtain permission from the appropriate agencies (including connection to a public sewer).
24hr Storage to Meet Building Regulations
The Klargester pump station range has been designed in accordance with Building Regulations Document H1 Foul Drainage, page 16. (Pumping Installations) Section 2.39. This states:
“Where foul drainage from a building is to be pumped, the effluent receiving chamber should be sized to contain 24 hour inflow to allow for disruption in service. The minimum daily discharge of foul drainage should be taken as 150 litres per head per day for domestic use. For other types of building, the capacity of the receiving chamber should be based on the calculated daily demand of the water intake for the building. Where only a proportion of the foul sewage is to be pumped, then the capacity should be based pro-rata. In all pumped systems the controls should be so arranged to optimise pump operation. The required 150 litres per head per day volume should reflect the storage volume in the station pump or station and overflow tanks.”
Ref: page 16. (Pumping Installations) Section 2.39
Klargester Product Range:
HillMaster
The HillMaster range offers a competitive solution to the pumping requirements of both domestic and industrial applications. Often it can be preferable to keep civil work and installation costs down to a minimum but such economy should not mean any shortfall in quality.
The 1.0m diameter units are manufactured in tough polyethylene using advanced rotational-moulding technology, while the 1.25, 1.8 and 2.6m diameter units are made from maintenance-free GRP. All units are engineered with the highest quality parts and fittings.
- High-level alarm as standard (optional as
marked *) - Various invert depths
- Internal lifting chains and guiderails** (as
specified) - Wide range of pump options including
macerators/solids handling/vortex - Pedestrian/vehicle covers
Owls Hall offer a full commissioning and after sales service involving planned maintenance visits. Please visit our servicing section for more information
** Please note, guiderails are not standard fitment on effluent pumpsets unless specified.
Owls Hall offer a full Installation service. Please visit our Installation section for more information.
HillMaster24
The HillMaster24 range has been specifically designed to meet the requirements of Building Regulations Document H1 Foul Drainage. This regulation recognises the need for pump stations to have a 24hr storage capacity in case of a disruption in service (such as a power failure).
This comprehensive range offers an advanced solution to larger domestic and industrial applications. For large-capacity flows (such as stormwater run-off from hard-standing areas), horizontal holding chambers are available in a comprehensive range of sizes.
- High-level alarm fitted as standard
- Various invert depths
- Internal lifting chains and guiderails fitted as standard
- Wide range of pump options includingmacerators/solids handling/vortex
- Combined chamber capacity up to 90,000 litres
- Pumping distances up to 1000 metres
- Pedestrian/vehicle covers
- Kiosks with warning beacons (option)
- Telemetry systems (option)
Owls Hall offer a full commissioning and after sales service involving planned maintenance visits. Please visit our servicing section for more information
Owls Hall offer a full Installation service. Please visit our Installation section for more information.
Effluent Pumpsets
A septic tank or treatment system pumpset can be used to disperse settled effluent when a site has a high water table or adverse invert levels. Installed after the septic tank or treatment system and pumping settled effluent up to an inspection chamber, flow to the drainage system then takes place by gravity in the normal way.
Domestic Sewage Pumpsets
If the main sewer is accessible but at a higher level to (or some distance from) the domestic foul drain, then a domestic sewage pumpset may be used to pump unsettled sewage directly to the main. Whilst single pump units are acceptable for individual houses, it is recommended that twin pumping systems be used for multiple dwellings.
Owls Hall offer a full Installation service. Please visit our Installation section for more information.
Surface Water Pumpsets
Due to the amount of rainwater that can fall in a short time period, Surface Water run-off is often the most demanding of all applications, whether hard-standing or roof areas.
Owls Hall offer a full Installation service. Please visit our Installation section for more information.
Compact Pump Systems for Wastewater Applications
The HillMaster range now includes a series of compact pump systems, designed for rapid installation, providing simple and speedy dewatering of buildings and areas below the sewer level.
Applications
- Outbuildings and extensions
- Cellar drainage
- External WCs
- Pool houses
Chambers are ideal for effluent and sewage, dependent on pump specification, required distance and lift. All units are suitable for pumping wastewater in accordance with DIN/EN 12056.
Features
- Ready for simple and immediate installation, minimal assembly required
- Fully adjustable for height and floor level alignment
- Non-return valves as standard
- Protective cover for protection during installation
- Manufactured from tough polyethylene
- Corrosion resistant
- Outlet pipe compression fittings as standard
Sewage Pump Performance Chamber A (40mm solids handling)
Effluent Pump Performance
Specification
Chamber Type | Chamber Dia. | Chamber Height | Base to Centre of Inlet | Base to Centre of Outlet | Inlet Dia. | Outlet Fitting for MDPE Pipe |
---|---|---|---|---|---|---|
A | 720 | 790-920 | 340 | 350 | 100/150 | 63 |
B | 530 | 670-800 | 340 | 350 | 100 | 50 |
Design
All compact systems consist of a polyethylene chamber fitted with a quality pump, float switch, non-return valves, pedestrian duty cover and frame, cover plate and all connections.
Installation & Operation
The access neck and cover are universally adjustable in height and can be rotated to allow easy alignment with flooring and landscaping design, independent of the inflow or discharge line directions. A protective cover for the access neck is supplied for use during installation to prevent backfill from damaging the access cover. Access neck extension piece is available as part of the package to facilitate a further 150mm inlet depth if required.
Owls Hall offer a full Installation service. Please visit our Installation section for more information.
With Klargester Pump Stations they have a full initial 12 month warranty covering all mechanical and electrical components against malfunction, provided the unit has not been subject to damage or abuse.
Pump Station Enquiry:
To allow us to accurately size and quote your specific system, please complete either our Online Pump Station Enquiry Form or alternatively, print our PDF Pump Station Enquiry Form and post or fax it to us.
Once we have received your enquiry form we will then evaluate your requirements and specify the appropriate system accordingly to allow us to provide a suitable quotation.